Actions

VFDs

From PROBOTIX :: wiki

Revision as of 12:02, 3 April 2016 by Admin (Talk | contribs)

VFD Wiring
VFD Wiring Diagram

Huangyang VFD

Huanyang VFD Manual

To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD014 - Acceleration - 3
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated








Sunfar VFD

Sunfar VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
    F0.2 = 1001 (for 0-10V Control) /1000 (for knob control)
    F0.5 = 3 (Acceleration time)
    F0.6 = 0 (Deceleration time)
    F0.13 = 220 (Volts)

F1.3=400 or 1000 set according your spindle F1.7=1 F1.8=2 F0.4= 400 or 1000 set according your spindle F1.9=3

F0.12=400 or 1000 set according your spindle