To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD014 - Acceleration - 3
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated








Sunfar VFD

Sunfar VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Running:low noise runningF0.0 = 4 (or 3 if you want to test using the knob on the VFD) F1.7=1 F0.2=1001 (or 1000 if you want to test using the knob on VFD) F1.8=2 F0.4= 400 or 1000 set according your spindle F1.9=3 F0.5=10 F0.6=10 F0.11=0 F0.12=400 or 1000 set according your spindle F0.13=220 F1.3=400 or 1000 set according your spindle - See more at: http://www.automationtechnologiesinc.com/products-page/cnc-spindle/kl-vfd03-300w-mini-type-integrated-universal-inverter-vfd#sthash.scilFXlD.dpuf