VFDs
From PROBOTIX :: wiki
Huangyang VFD
Contents
To change settings:
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD014 - Acceleration - 3
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated
Sunfar VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Running:low noise runningF0.0 = 4 (or 3 if you want to test using the knob on the VFD) F1.7=1 F0.2=1001 (or 1000 if you want to test using the knob on VFD) F1.8=2 F0.4= 400 or 1000 set according your spindle F1.9=3 F0.5=10 F0.6=10 F0.11=0 F0.12=400 or 1000 set according your spindle F0.13=220 F1.3=400 or 1000 set according your spindle - See more at: http://www.automationtechnologiesinc.com/products-page/cnc-spindle/kl-vfd03-300w-mini-type-integrated-universal-inverter-vfd#sthash.scilFXlD.dpuf