Difference between revisions of "VFDs"
From PROBOTIX :: wiki
m (Admin moved page VFD Spindles to VFDs: related to spindles but not actually spindles) |
m (→Setting needed for galaxy series machines:: added leading zeros) |
||
(One intermediate revision by the same user not shown) | |||
Line 38: | Line 38: | ||
===Setting needed for galaxy series machines:=== | ===Setting needed for galaxy series machines:=== | ||
− | * F0. | + | * F0.00 = 1 (for 0-10V Control) or 3 (for knob control) |
− | * F0. | + | * F0.02 = 1000 (for panel [RUN] button) |
− | * F0. | + | * F0.04= 400 (Spindle Frequency) |
− | * F0. | + | * F0.05 = 5.0 (Acceleration time) |
* F0.12 = 400 (Basic Frequency) | * F0.12 = 400 (Basic Frequency) | ||
* F0.13 = 220 (Volts) | * F0.13 = 220 (Volts) | ||
− | * F1. | + | * F1.03 = 400 (Max Frequency) |
− | * F1. | + | * F1.07=1 |
− | * F1. | + | * F1.08=2 |
− | * F1. | + | * F1.09=3 |
− | + | ||
== Sunfar E500 VFD == | == Sunfar E500 VFD == | ||
Line 64: | Line 63: | ||
===Setting needed for galaxy series machines:=== | ===Setting needed for galaxy series machines:=== | ||
− | * F0. | + | * F0.00 = 1 (for 0-10V Control) or 3 (for knob control) |
− | * F0. | + | * F0.02 = 1001 (for panel [RUN] button) |
− | * F0. | + | * F0.04= 400 (Spindle Frequency) |
− | * F0. | + | * F0.05 = 5.0 (Acceleration time) |
* F0.11 = 0 (Torque Boost) | * F0.11 = 0 (Torque Boost) | ||
* F0.12 = 400 (Basic Frequency) | * F0.12 = 400 (Basic Frequency) |
Latest revision as of 14:18, 18 January 2019
Contents
Huangyang VFD
To change settings:
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD014 - Acceleration - 3
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated
Sunfar E300 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.02 = 1000 (for panel [RUN] button)
- F0.04= 400 (Spindle Frequency)
- F0.05 = 5.0 (Acceleration time)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.03 = 400 (Max Frequency)
- F1.07=1
- F1.08=2
- F1.09=3
Sunfar E500 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.02 = 1001 (for panel [RUN] button)
- F0.04= 400 (Spindle Frequency)
- F0.05 = 5.0 (Acceleration time)
- F0.11 = 0 (Torque Boost)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.00 = 0.4 (AI Lower Limit)
- F1.01 = 10 (AI Upper Limit)
- F1.03 = 0 (Min Freq)
- F1.04 = 400 (Max Freq)
- F1.08 = 11 (Terminal 1 Function)