Huangyang VFD
+
  
===To change settings:===
+
== Huangyang VFD ==
 +
[[File:VFD_wiring_diagram.jpg|thumb|400px|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
  
:#Press [PROGRAM]
+
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
:#Use arrow keys to change to program number your looking to change
+
 
:#Press [SET]
+
===To change settings:===
:#Use the arrow keys to change the value to appropriate value
+
# Press [PROGRAM]
:#Press [SET] to save the value
+
# Use arrow keys to change to program number your looking to change
 +
# Press [SET]
 +
# Use the arrow keys to change the value to appropriate value
 +
# Press [SET] to save the value
  
 
===Setting needed for galaxy series machines:===
 
===Setting needed for galaxy series machines:===
 
+
* PD001 – Source of Run Command –  0
:*PD001 – Source of Run Command –  0
+
* PD002 – Source of Operating Frequency –  1
:*PD002 – Source of Operating Frequency –  1
+
* PD014 - Acceleration - 3
:*PD014 - Acceleration - 3
+
* PD070 – Analog Input 0-10V –  0
:*PD070 – Analog Input 0-10V –  0
+
* PD144 – Rated Motor Revolution –  3000
:*PD144 – Rated Motor Revolution –  3000
+
  
 
===Displaying RPM instead of Hz:===
 
===Displaying RPM instead of Hz:===
 
 
Press the arrow over key until the Rott light is illuminated
 
Press the arrow over key until the Rott light is illuminated
  
  
 +
== Sunfar E300 VFD ==
 +
[[File:VFD_Sunfar_E300.jpg|thumb|400px|alt=Sunfar E300 VFD Wiring|Sunfar E300 VFD Wiring Diagram]]
 +
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
  
<hr>
+
===To change settings:===
 +
# Press [SET]
 +
# Use arrow keys to change to program number your looking to change
 +
# Press [SET]
 +
# Use the arrow keys to change the value to appropriate value
 +
# Press [SET] to save the value
 +
# Press [ESC] to exit programming mode
  
Sunfar VFD
 
  
 +
===Setting needed for galaxy series machines:===
 +
* F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
 +
* F0.02 = 1000 (for panel [RUN] button)
 +
* F0.04= 400 (Spindle Frequency)
 +
* F0.05 = 5.0 (Acceleration time)
 +
* F0.12 = 400 (Basic Frequency)
 +
* F0.13 = 220 (Volts)
 +
* F1.03 = 400 (Max Frequency)
 +
* F1.07=1
 +
* F1.08=2
 +
* F1.09=3
  
 +
== Sunfar E500 VFD ==
 +
[[File:VFD_Sunfar_E500.jpg|thumb|400px|alt=Sunfar E500 VFD Wiring|Sunfar E500 VFD Wiring Diagram]]
 +
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
  
Running:low noise runningF0.0 = 4 (or 3 if you want to test using the knob on the VFD) F1.7=1 F0.2=1001 (or 1000 if you want to test using the knob on VFD) F1.8=2 F0.4= 400 or 1000 set according your spindle F1.9=3 F0.5=10 F0.6=10 F0.11=0 F0.12=400 or 1000 set according your spindle F0.13=220 F1.3=400 or 1000 set according your spindle - See more at: http://www.automationtechnologiesinc.com/products-page/cnc-spindle/kl-vfd03-300w-mini-type-integrated-universal-inverter-vfd#sthash.scilFXlD.dpuf
+
===To change settings:===
 +
# Press [SET]
 +
# Use arrow keys to change to program number your looking to change
 +
# Press [SET]
 +
# Use the arrow keys to change the value to appropriate value
 +
# Press [SET] to save the value
 +
# Press [ESC] to exit programming mode
 +
 
 +
 
 +
===Setting needed for galaxy series machines:===
 +
* F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
 +
* F0.02 = 1001 (for panel [RUN] button)
 +
* F0.04= 400 (Spindle Frequency)
 +
* F0.05 = 5.0 (Acceleration time)
 +
* F0.11 = 0 (Torque Boost)
 +
* F0.12 = 400 (Basic Frequency)
 +
* F0.13 = 220 (Volts)
 +
* F1.00 = 0.4 (AI Lower Limit)
 +
* F1.01 = 10 (AI Upper Limit)
 +
* F1.03 = 0 (Min Freq)
 +
* F1.04 = 400 (Max Freq)
 +
* F1.08 = 11 (Terminal 1 Function)

Latest revision as of 14:18, 18 January 2019


Huangyang VFD

Huanyang VFD Wiring
Huanyang VFD Wiring Diagram

Huanyang VFD Manual

To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD014 - Acceleration - 3
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated


Sunfar E300 VFD

Sunfar E300 VFD Wiring
Sunfar E300 VFD Wiring Diagram

Sunfar E300 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.02 = 1000 (for panel [RUN] button)
  • F0.04= 400 (Spindle Frequency)
  • F0.05 = 5.0 (Acceleration time)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.03 = 400 (Max Frequency)
  • F1.07=1
  • F1.08=2
  • F1.09=3

Sunfar E500 VFD

Sunfar E500 VFD Wiring
Sunfar E500 VFD Wiring Diagram

Sunfar E500 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.00 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.02 = 1001 (for panel [RUN] button)
  • F0.04= 400 (Spindle Frequency)
  • F0.05 = 5.0 (Acceleration time)
  • F0.11 = 0 (Torque Boost)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.00 = 0.4 (AI Lower Limit)
  • F1.01 = 10 (AI Upper Limit)
  • F1.03 = 0 (Min Freq)
  • F1.04 = 400 (Max Freq)
  • F1.08 = 11 (Terminal 1 Function)