− | [[File:VFD_wiring_diagram.jpg|thumb|400px | + | == Huangyang VFD == |
− | + | [[File:VFD_wiring_diagram.jpg|thumb|400px|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]] | |
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]] | [[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]] | ||
Line 25: | Line 25: | ||
− | + | == Sunfar E300 VFD == | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | Sunfar E300 VFD | + | |
− | + | ||
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]] | [[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]] | ||
Line 65: | Line 52: | ||
− | + | == Sunfar E500 VFD == | |
− | + | ||
− | Sunfar E500 VFD | + | |
− | + | ||
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]] | [[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]] | ||
Revision as of 21:37, 8 March 2018
Contents
Huangyang VFD
To change settings:
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD014 - Acceleration - 3
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated
Sunfar E300 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.2 = 1000 (for panel [RUN] button)
- F0.4= 400 (Spindle Frequency)
- F0.5 = 5.0 (Acceleration time)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.3 = 400 (Max Frequency)
- F1.7=1
- F1.8=2
- F1.9=3
Sunfar E500 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.2 = 1001 (for panel [RUN] button)
- F0.4= 400 (Spindle Frequency)
- F0.5 = 5.0 (Acceleration time)
- F0.11 = 0 (Torque Boost)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.00 = 0.4 (AI Lower Limit)
- F1.01 = 10 (AI Upper Limit)
- F1.03 = 0 (Min Freq)
- F1.04 = 400 (Max Freq)
- F1.08 = 11 (Terminal 1 Function)