[[File:VFD_wiring_diagram.jpg|thumb|400px|left|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
+
== Huangyang VFD ==
Huangyang VFD
+
[[File:VFD_wiring_diagram.jpg|thumb|400px|alt=Huanyang VFD Wiring|Huanyang VFD Wiring Diagram]]
  
 
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
 
[[Media:Huanyang_SL_Series_Manual.pdf | Huanyang VFD Manual]]
Line 25: Line 25:
  
  
 
+
== Sunfar E300 VFD ==
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
 
+
<hr>
+
 
+
Sunfar E300 VFD
+
 
+
 
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
 
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
  
Line 65: Line 52:
  
  
<hr>
+
== Sunfar E500 VFD ==
 
+
Sunfar E500 VFD
+
 
+
 
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
 
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
  

Revision as of 21:37, 8 March 2018

Huangyang VFD

Huanyang VFD Wiring
Huanyang VFD Wiring Diagram

Huanyang VFD Manual

To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD014 - Acceleration - 3
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated


Sunfar E300 VFD

Sunfar E300 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.2 = 1000 (for panel [RUN] button)
  • F0.4= 400 (Spindle Frequency)
  • F0.5 = 5.0 (Acceleration time)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.3 = 400 (Max Frequency)
  • F1.7=1
  • F1.8=2
  • F1.9=3


Sunfar E500 VFD

Sunfar E500 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.2 = 1001 (for panel [RUN] button)
  • F0.4= 400 (Spindle Frequency)
  • F0.5 = 5.0 (Acceleration time)
  • F0.11 = 0 (Torque Boost)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.00 = 0.4 (AI Lower Limit)
  • F1.01 = 10 (AI Upper Limit)
  • F1.03 = 0 (Min Freq)
  • F1.04 = 400 (Max Freq)
  • F1.08 = 11 (Terminal 1 Function)