Actions

Difference between revisions of "VFDs"

From PROBOTIX :: wiki

Line 39: Line 39:
 
Sunfar E300 VFD
 
Sunfar E300 VFD
  
[[Media:Sunfar_VFD.pdf | Sunfar VFD Manual]]
+
[[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]]
  
 
===To change settings:===
 
===To change settings:===
Line 56: Line 56:
 
:*F0.2 = 1000 (for panel [RUN] button)
 
:*F0.2 = 1000 (for panel [RUN] button)
 
:*F0.4= 400 (Spindle Frequency)  
 
:*F0.4= 400 (Spindle Frequency)  
:*F0.5 = 3 (Acceleration time)
+
:*F0.5 = 5.0 (Acceleration time)  
:*F0.6 = 0 (Deceleration time)
+
 
:*F0.12 = 400 (Basic Frequency)
 
:*F0.12 = 400 (Basic Frequency)
 
:*F0.13 = 220 (Volts)  
 
:*F0.13 = 220 (Volts)  
Line 64: Line 63:
 
:*F1.8=2  
 
:*F1.8=2  
 
:*F1.9=3
 
:*F1.9=3
 +
 +
 +
<hr>
 +
 +
Sunfar E500 VFD
 +
 +
[[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]]
 +
 +
===To change settings:===
 +
 +
:#Press [SET]
 +
:#Use arrow keys to change to program number your looking to change
 +
:#Press [SET]
 +
:#Use the arrow keys to change the value to appropriate value
 +
:#Press [SET] to save the value
 +
:#Press [ESC] to exit programming mode
 +
 +
 +
===Setting needed for galaxy series machines:===
 +
 +
:*F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
 +
:*F0.2 = 1001 (for panel [RUN] button)
 +
:*F0.4= 400 (Spindle Frequency)
 +
:*F0.5 = 5.0 (Acceleration time)
 +
:*F0.11 = 0 (Torque Boost)
 +
:*F0.12 = 400 (Basic Frequency)
 +
:*F0.13 = 220 (Volts)
 +
:*F1.00 = 0.4 (AI Lower Limit)
 +
:*F1.01 = 10 (AI Upper Limit)
 +
:*F1.03 = 0 (Min Freq)
 +
:*F1.04 = 400 (Max Freq)
 +
:*F1.08 = 11 (Terminal 1 Function)

Revision as of 06:45, 1 May 2017

Huanyang VFD Wiring
Huanyang VFD Wiring Diagram

Huangyang VFD

Huanyang VFD Manual

To change settings:

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD014 - Acceleration - 3
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated








Sunfar E300 VFD

Sunfar E300 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.2 = 1000 (for panel [RUN] button)
  • F0.4= 400 (Spindle Frequency)
  • F0.5 = 5.0 (Acceleration time)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.3 = 400 (Max Frequency)
  • F1.7=1
  • F1.8=2
  • F1.9=3



Sunfar E500 VFD

Sunfar E500 VFD Manual

To change settings:

  1. Press [SET]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value
  6. Press [ESC] to exit programming mode


Setting needed for galaxy series machines:

  • F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
  • F0.2 = 1001 (for panel [RUN] button)
  • F0.4= 400 (Spindle Frequency)
  • F0.5 = 5.0 (Acceleration time)
  • F0.11 = 0 (Torque Boost)
  • F0.12 = 400 (Basic Frequency)
  • F0.13 = 220 (Volts)
  • F1.00 = 0.4 (AI Lower Limit)
  • F1.01 = 10 (AI Upper Limit)
  • F1.03 = 0 (Min Freq)
  • F1.04 = 400 (Max Freq)
  • F1.08 = 11 (Terminal 1 Function)