Difference between revisions of "VFDs"
From PROBOTIX :: wiki
Line 39: | Line 39: | ||
Sunfar E300 VFD | Sunfar E300 VFD | ||
− | [[Media:Sunfar_VFD.pdf | Sunfar VFD Manual]] | + | [[Media:Sunfar_VFD.pdf | Sunfar E300 VFD Manual]] |
===To change settings:=== | ===To change settings:=== | ||
Line 56: | Line 56: | ||
:*F0.2 = 1000 (for panel [RUN] button) | :*F0.2 = 1000 (for panel [RUN] button) | ||
:*F0.4= 400 (Spindle Frequency) | :*F0.4= 400 (Spindle Frequency) | ||
− | :*F0.5 = | + | :*F0.5 = 5.0 (Acceleration time) |
− | + | ||
:*F0.12 = 400 (Basic Frequency) | :*F0.12 = 400 (Basic Frequency) | ||
:*F0.13 = 220 (Volts) | :*F0.13 = 220 (Volts) | ||
Line 64: | Line 63: | ||
:*F1.8=2 | :*F1.8=2 | ||
:*F1.9=3 | :*F1.9=3 | ||
+ | |||
+ | |||
+ | <hr> | ||
+ | |||
+ | Sunfar E500 VFD | ||
+ | |||
+ | [[Media:SunfarE500.pdf | Sunfar E500 VFD Manual]] | ||
+ | |||
+ | ===To change settings:=== | ||
+ | |||
+ | :#Press [SET] | ||
+ | :#Use arrow keys to change to program number your looking to change | ||
+ | :#Press [SET] | ||
+ | :#Use the arrow keys to change the value to appropriate value | ||
+ | :#Press [SET] to save the value | ||
+ | :#Press [ESC] to exit programming mode | ||
+ | |||
+ | |||
+ | ===Setting needed for galaxy series machines:=== | ||
+ | |||
+ | :*F0.0 = 1 (for 0-10V Control) or 3 (for knob control) | ||
+ | :*F0.2 = 1001 (for panel [RUN] button) | ||
+ | :*F0.4= 400 (Spindle Frequency) | ||
+ | :*F0.5 = 5.0 (Acceleration time) | ||
+ | :*F0.11 = 0 (Torque Boost) | ||
+ | :*F0.12 = 400 (Basic Frequency) | ||
+ | :*F0.13 = 220 (Volts) | ||
+ | :*F1.00 = 0.4 (AI Lower Limit) | ||
+ | :*F1.01 = 10 (AI Upper Limit) | ||
+ | :*F1.03 = 0 (Min Freq) | ||
+ | :*F1.04 = 400 (Max Freq) | ||
+ | :*F1.08 = 11 (Terminal 1 Function) |
Revision as of 06:45, 1 May 2017
Huangyang VFD
Contents
To change settings:
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD014 - Acceleration - 3
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated
Sunfar E300 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.2 = 1000 (for panel [RUN] button)
- F0.4= 400 (Spindle Frequency)
- F0.5 = 5.0 (Acceleration time)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.3 = 400 (Max Frequency)
- F1.7=1
- F1.8=2
- F1.9=3
Sunfar E500 VFD
To change settings:
- Press [SET]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
- Press [ESC] to exit programming mode
Setting needed for galaxy series machines:
- F0.0 = 1 (for 0-10V Control) or 3 (for knob control)
- F0.2 = 1001 (for panel [RUN] button)
- F0.4= 400 (Spindle Frequency)
- F0.5 = 5.0 (Acceleration time)
- F0.11 = 0 (Torque Boost)
- F0.12 = 400 (Basic Frequency)
- F0.13 = 220 (Volts)
- F1.00 = 0.4 (AI Lower Limit)
- F1.01 = 10 (AI Upper Limit)
- F1.03 = 0 (Min Freq)
- F1.04 = 400 (Max Freq)
- F1.08 = 11 (Terminal 1 Function)