Difference between revisions of "VFDs"
From PROBOTIX :: wiki
(→==To change settings:=) |
|||
Line 11: | Line 11: | ||
:*PD001 – Source of Run Command – 0 | :*PD001 – Source of Run Command – 0 | ||
:*PD002 – Source of Operating Frequency – 1 | :*PD002 – Source of Operating Frequency – 1 | ||
+ | :*PD014 - Acceleration - 3 | ||
:*PD070 – Analog Input 0-10V – 0 | :*PD070 – Analog Input 0-10V – 0 | ||
:*PD144 – Rated Motor Revolution – 3000 | :*PD144 – Rated Motor Revolution – 3000 |
Revision as of 13:23, 15 October 2015
To change settings:
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD014 - Acceleration - 3
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated