Difference between revisions of "VFDs"
From PROBOTIX :: wiki
Line 1: | Line 1: | ||
− | == To change settings:== | + | == ==To change settings:=== |
− | #Press [PROGRAM] | + | :#Press [PROGRAM] |
− | #Use arrow keys to change to program number your looking to change | + | :#Use arrow keys to change to program number your looking to change |
− | #Press [SET] | + | :#Press [SET] |
− | #Use the arrow keys to change the value to appropriate value | + | :#Use the arrow keys to change the value to appropriate value |
− | #Press [SET] to save the value | + | :#Press [SET] to save the value |
− | == Setting needed for galaxy series machines:== | + | ===Setting needed for galaxy series machines:=== |
− | PD001 – Source of Run Command – 0 | + | :*PD001 – Source of Run Command – 0 |
− | PD002 – Source of Operating Frequency – 1 | + | :*PD002 – Source of Operating Frequency – 1 |
− | PD070 – Analog Input 0-10V – 0 | + | :*PD070 – Analog Input 0-10V – 0 |
− | PD144 – Rated Motor Revolution – 3000 | + | :*PD144 – Rated Motor Revolution – 3000 |
− | == Displaying RPM instead of Hz:== | + | ===Displaying RPM instead of Hz:=== |
Press the arrow over key until the Rott light is illuminated | Press the arrow over key until the Rott light is illuminated | ||
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]] | [[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]] |
Revision as of 09:38, 31 August 2015
==To change settings:=
- Press [PROGRAM]
- Use arrow keys to change to program number your looking to change
- Press [SET]
- Use the arrow keys to change the value to appropriate value
- Press [SET] to save the value
Setting needed for galaxy series machines:
- PD001 – Source of Run Command – 0
- PD002 – Source of Operating Frequency – 1
- PD070 – Analog Input 0-10V – 0
- PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated