Actions

Difference between revisions of "VFDs"

From PROBOTIX :: wiki

Line 1: Line 1:
== To change settings:==
+
== ==To change settings:===
  
#Press [PROGRAM]
+
:#Press [PROGRAM]
#Use arrow keys to change to program number your looking to change
+
:#Use arrow keys to change to program number your looking to change
#Press [SET]
+
:#Press [SET]
#Use the arrow keys to change the value to appropriate value
+
:#Use the arrow keys to change the value to appropriate value
#Press [SET] to save the value
+
:#Press [SET] to save the value
  
== Setting needed for galaxy series machines:==
+
===Setting needed for galaxy series machines:===
  
PD001 – Source of Run Command –  0
+
:*PD001 – Source of Run Command –  0
PD002 – Source of Operating Frequency –  1
+
:*PD002 – Source of Operating Frequency –  1
PD070 – Analog Input 0-10V –  0
+
:*PD070 – Analog Input 0-10V –  0
PD144 – Rated Motor Revolution –  3000
+
:*PD144 – Rated Motor Revolution –  3000
  
== Displaying RPM instead of Hz:==
+
===Displaying RPM instead of Hz:===
  
 
Press the arrow over key until the Rott light is illuminated
 
Press the arrow over key until the Rott light is illuminated
  
 
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]]
 
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]]

Revision as of 09:38, 31 August 2015

==To change settings:=

  1. Press [PROGRAM]
  2. Use arrow keys to change to program number your looking to change
  3. Press [SET]
  4. Use the arrow keys to change the value to appropriate value
  5. Press [SET] to save the value

Setting needed for galaxy series machines:

  • PD001 – Source of Run Command – 0
  • PD002 – Source of Operating Frequency – 1
  • PD070 – Analog Input 0-10V – 0
  • PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated

VFD Wiring
VFD Wiring Diagram