To change settings:
1. Press [PROGRAM] 2. Use arrow keys to change to program number your looking to change 3. Press [SET] 4. Use the arrow keys to change the value to appropriate value 5. Press [SET] to save the value
Setting needed for galaxy series machines:
PD001 – Source of Run Command – 0 PD002 – Source of Operating Frequency – 1 PD070 – Analog Input 0-10V – 0 PD144 – Rated Motor Revolution – 3000
Displaying RPM instead of Hz:
Press the arrow over key until the Rott light is illuminated