Actions

Difference between revisions of "VFDs"

From PROBOTIX :: wiki

Line 1: Line 1:
 +
To change settings:
  
 +
1. Press [PROGRAM]
 +
2. Use arrow keys to change to program number your looking to change
 +
3. Press [SET]
 +
4. Use the arrow keys to change the value to appropriate value
 +
5. Press [SET] to save the value
 +
 +
Setting needed for galaxy series machines:
 +
 +
PD001 – Source of Run Command –  0
 +
PD002 – Source of Operating Frequency –  1
 +
PD070 – Analog Input 0-10V –  0
 +
PD144 – Rated Motor Revolution –  3000
 +
 +
Displaying RPM instead of Hz:
 +
 +
Press the arrow over key until the Rott light is illuminated
  
 
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]]
 
[[File:VFD_wiring_diagram.jpg|thumb|500px|left|alt=VFD Wiring|VFD Wiring Diagram]]

Revision as of 09:35, 31 August 2015

To change settings:

1. Press [PROGRAM] 2. Use arrow keys to change to program number your looking to change 3. Press [SET] 4. Use the arrow keys to change the value to appropriate value 5. Press [SET] to save the value

Setting needed for galaxy series machines:

PD001 – Source of Run Command – 0 PD002 – Source of Operating Frequency – 1 PD070 – Analog Input 0-10V – 0 PD144 – Rated Motor Revolution – 3000

Displaying RPM instead of Hz:

Press the arrow over key until the Rott light is illuminated

VFD Wiring
VFD Wiring Diagram